• DocumentCode
    1060224
  • Title

    An accurate AC-Dc voltage transfer standard test system using the differential and the dual-channel method

  • Author

    Takahashi, K. ; Sasaki, H. ; Klonz, M. ; Endo, T.

  • Author_Institution
    Japan Electric Meters Inspection Corp., Tokyo, Japan
  • Volume
    42
  • Issue
    2
  • fYear
    1993
  • fDate
    4/1/1993 12:00:00 AM
  • Firstpage
    630
  • Lastpage
    634
  • Abstract
    In the Electrotechnical Laboratory (ETL) the accuracy of the AC-DC voltage transfer difference was improved for the voltage range of 1-20 V in the frequency range from 10 Hz to 100 kHz. At the same time, the AC-Dc transfer standards and the measurement system which is used in the Japan Electric Meter Inspection Corporation (JEMIC) were also improved. The system is realized by applying an improved differential and a dual-channel method. The test repeatability is better than 1 ppm for nominal test voltages. The voltage and frequency measurement ranges are extended up to 200 V and up to 1 MHz. The whole system is controlled by a desktop computer with an optically isolated GP-IB bus system
  • Keywords
    automatic test equipment; frequency measurement; measurement standards; microcomputer applications; voltage measurement; 1 to 20 V; 10 Hz to 100 kHz; 100 kHz to 1 MHz; 20 to 200 V; AC-Dc voltage transfer standard; ATE; Electrotechnical Laboratory; Japan Electric Meter Inspection Corporation; desktop computer; differential method; dual-channel method; frequency measurement; optically isolated GP-IB bus; test repeatability; voltage measurement; Electric variables measurement; Frequency; Inspection; Laboratories; Measurement standards; Optical computing; System testing; Time measurement; Voltage; Watthour meters;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.278643
  • Filename
    278643