DocumentCode
1062585
Title
A new electrostatic discharge failure mode
Author
Woods, Murray H. ; Gear, Gary
Author_Institution
Intel Corporation, Santa Clara, CA
Volume
26
Issue
1
fYear
1979
fDate
1/1/1979 12:00:00 AM
Firstpage
16
Lastpage
21
Abstract
A new electrostatic discharge failure mode was discovered which affects MOS LSI components in hermetic packages with nonconductive lids. Failure can be induced by spraying package lids with canned coolant. It is shown that charge from the freeze spray causes breakdown in the air-gap between the die surface and the lid. As a result, localized surface charging and field inversion occurs in the array, which produces leakage currents and circuit failure. The failure mode can be characterized by its recovery with either a strong UV exposure to the die surface or a DI water rinse.
Keywords
Air gaps; Coolants; Electric breakdown; Electrostatic discharge; Large scale integration; Leakage current; Packaging; Spraying; Surface charging; Surface discharges;
fLanguage
English
Journal_Title
Electron Devices, IEEE Transactions on
Publisher
ieee
ISSN
0018-9383
Type
jour
DOI
10.1109/T-ED.1979.19372
Filename
1479950
Link To Document