DocumentCode
1063601
Title
Forecast of VLSI processing—A historical review of the first dry-processed IC
Author
Penn, Thomas Clifton
Author_Institution
Texas Instruments Inc., Dallas, TX
Volume
26
Issue
4
fYear
1979
fDate
4/1/1979 12:00:00 AM
Firstpage
640
Lastpage
643
Abstract
The principles of the flat-plate, radial flow plasma reactor and its rapid proliferation into production at Texas Instruments will be reviewed. From this foundation it was logical to attempt the fabrication of a semiconductor integrated circuit by all dry means. An electrically operating double-level metal CCD shift register was fabricated in late 1975 with no liquids other than DI water and photoresist. Silicon, oxide, nitride, and aluminum were all plasma-etched. Photoresist was both developed and removed by novel dry means.
Keywords
Charge coupled devices; Fabrication; Inductors; Instruments; Liquids; Plasmas; Production; Resists; Shift registers; Very large scale integration;
fLanguage
English
Journal_Title
Electron Devices, IEEE Transactions on
Publisher
ieee
ISSN
0018-9383
Type
jour
DOI
10.1109/T-ED.1979.19471
Filename
1480049
Link To Document