• DocumentCode
    1063876
  • Title

    Motion Artifacts of Extended High Frame Rate Imaging

  • Author

    Wang, Jing ; Lu, Jian-Yu

  • Author_Institution
    Toledo Univ., Toledo
  • Volume
    54
  • Issue
    7
  • fYear
    2007
  • fDate
    7/1/2007 12:00:00 AM
  • Firstpage
    1303
  • Lastpage
    1315
  • Abstract
    Based on the high frame rate (HFR) imaging method developed in our lab, an extended high frame rate imaging method with various transmission schemes was developed recently. In this method, multiple, limited- diffraction array beams or steered plane wave transmissions are used to increase image resolution and field of view as well as to reduce sidelobes. Furthermore, the multiple, limited-diffraction array beam transmissions can be approximated with square-wave aperture weightings, allowing one or two transmitters to be used with a multielement array transducer to simplify imaging systems. By varying the number of transmissions, the extended HFR imaging method allows a continuous trade-off between image quality and frame rate. Because multiple transmissions are needed to obtain one frame of image for the method, motion could cause phase misalignment and thus produce artifacts, reducing image contrast and resolution and leading to an inaccurate clinical interpretation of images. Therefore, it is important to study how motion affects the method and provide a useful guidance of using the method properly in various applications. In this paper, computer simulations, in vitro and in vivo experiments were performed to study the effects of motion on the method in different conditions. Results show that a number of factors may affect the motion effects. However, it was found that the extended HFR imaging method is not sensitive to the motions commonly encountered in the clinical applications, as is demonstrated by an in vivo heart experiment, unless the number of transmissions is large and objects are moving at a high velocity near the surface of a transducer.
  • Keywords
    biomedical ultrasonics; cardiology; image motion analysis; image resolution; medical image processing; ultrasonic transducers; extended high frame rate imaging; heart; image contrast; image resolution; motion artifacts; multielement array transducer; multiple limited-diffraction array beams; phase misalignment; square-wave aperture weightings; steered plane wave transmissions; Apertures; Application software; Computer simulation; Diffraction; High-resolution imaging; Image quality; Image resolution; In vivo; Transducers; Transmitters; Algorithms; Artifacts; Image Enhancement; Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography; Video Recording;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2007.391
  • Filename
    4277147