DocumentCode
106412
Title
Baseline wander removal of ECG signals using Hilbert vibration decomposition
Author
Sharma, H. ; Sharma, K.K.
Author_Institution
Dept. of Electron. & Commun., Malviya Nat. Inst. of Technol., Jaipur, India
Volume
51
Issue
6
fYear
2015
fDate
3 19 2015
Firstpage
447
Lastpage
449
Abstract
A technique to remove baseline wander (BW) from electrocardiogram (ECG) signals based on the Hilbert vibration decomposition (HVD) technique is presented. It is proposed that the first component (highest energy component) obtained using the HVD of the ECG signal corresponds to the BW signal in it. The proposed technique is compared with the baseline removal method based on the empirical mode decomposition technique and mathematical morphology in terms of the correlation criterion and signal-to-noise ratio. The simulations were performed using artificial BWs of different amplitudes added in the ECG recordings and it is seen that the proposed technique for BW removal performs better in most of the cases of severe baseline wander distortions.
Keywords
Hilbert transforms; electrocardiography; medical signal processing; BW signal; ECG recordings; ECG signals; EMD; HVD; Hilbert vibration decomposition technique; baseline removal method; baseline wander distortions; baseline wander removal; correlation criterion; electrocardiogram signals; empirical mode decomposition technique; mathematical morphology; signal-to-noise ratio;
fLanguage
English