    A statistical analysis of the received signal from blood during laminar flow

  • Author

    Ferrara, Katherine W. ; Algazi, V. Ralph

  • Author_Institution
    Riverside Res. Inst., New York, NY, USA
  • Volume
    41
  • Issue
    2
  • fYear
    1994
  • fDate
    3/1/1994 12:00:00 AM
  • Firstpage
    185
  • Lastpage
    198
  • Abstract
    In order to determine the limiting velocity resolution that can be achieved using ultrasound, and to provide a model which can be generalized for the analysis of disturbed flow, a theoretical and experimental evaluation of the statistics of the received signal from laminar flow following the transmission of a train of short pulses is presented. The authors derive the autocorrelation function and determine the length of the correlated signal for various flow rates, comparing experimental measurements to theoretical predictions. High resolution experimental RF M-mode images are used to verify the theoretical model. Using a fluid with a density, viscosity, volume concentration, particle size, and speed of sound which is similar to that of blood, the authors show that the signal remains correlated for a long interval under many conditions of clinical interest. Including a comparison with experimental data, the effect of the lateral transit time through the sample volume and the axial velocity spread within the sample volume on the correlation of the received signal is evaluated. When a significant range of velocity components is present within the sample volume, this range is the limiting factor in the length of the correlated signal interval. Therefore, the use of a wideband signal, which reduces the sample volume size, produces a returned signal that may be correlated for a larger number of pulses, or for a longer time.<>
  • Keywords
    biomedical measurement; biomedical ultrasonics; flow measurement; haemodynamics; laminar flow; statistical analysis; RF M-mode images; autocorrelation function; axial velocity spread; disturbed flow analysis; flow rate; laminar blood flow; lateral transit time; medical ultrasonic measurement; received signal statistical analysis; sample volume size; short pulses train; velocity components; wideband signal; Autocorrelation; Blood; Image resolution; Length measurement; Radio frequency; Signal analysis; Signal resolution; Statistical analysis; Ultrasonic imaging; Viscosity;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.279131
  • Filename
    279131