Title :
Consideration of measurement of electrostriction in quartz using Bragg reflection of X-rays
Author :
Sherman, John H., Jr.
Author_Institution :
2022 Woodcrest Drive, Lynchburg, VA 24503, USA
fDate :
3/1/1994 12:00:00 AM
Abstract :
Calculation shows that the linear piezoelectric effect should be readily demonstrated in X-cut quartz by Bragg reflection of X-rays, equipment for which is available in every crystal finishing room. Electrostriction should also be observable and measurable in X-cut, Y-cut and Z-cut quartz, and in other cuts having their major surfaces parallel to X-ray diffracting planes of the crystal. Mechanical compression of the quartz due to the charge on the electrodes must be considered.<>
Keywords :
X-ray diffraction examination of materials; electrostriction; piezoelectric materials; quartz; Bragg reflection; SiO/sub 2/; X-cut; X-ray diffracting planes; Y-cut; Z-cut; crystal; electrostriction measurement; linear piezoelectric effect; mechanical compression; quartz; Differential equations; Electric variables measurement; Electrodes; Electrostriction; Finishing; Laboratories; Lattices; Piezoelectric effect; Reflection; X-ray diffraction;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on