• DocumentCode
    1064508
  • Title

    The TIGRESS DAQ/Trigger System

  • Author

    Martin, J.P. ; Mercier, C. ; Starinski, N. ; Pearson, C.J. ; Amaudruz, P.-A.

  • Author_Institution
    Univ. de Montreal, Montreal
  • Volume
    55
  • Issue
    1
  • fYear
    2008
  • Firstpage
    84
  • Lastpage
    90
  • Abstract
    The TIGRESS spectrometer is an array of escape suppressed, highly segmented, HPGe clover detectors, consisting of 896 channels, with around 1000 auxiliary detector channels available. The acquisition system is all digital, each detector signal is digitized and any filtering and subsequent processing is performed digitally. The system has been designed to integrate data flow, clock distribution, trigger, and acquisition control through the same serial links. A hierarchical trigger system is implemented, allowing various combinations of incoming trigger requests to be decided locally, or passed to any of the higher levels for final decision.
  • Keywords
    data acquisition; gamma-ray detection; gamma-ray spectrometers; germanium radiation detectors; high energy physics instrumentation computing; nuclear electronics; physical instrumentation control; trigger circuits; DAQ; HPGe clover detectors; TIGRESS spectrometer; data acquisition control; gamma-ray spectrometer; trigger system; Clocks; Control systems; Data acquisition; Detectors; Digital filters; Filtering; Sensor arrays; Signal detection; Signal processing; Spectroscopy; Data acquisition; detectors; signal processing; triggering;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2007.910853
  • Filename
    4448503