DocumentCode
1065044
Title
Dielectric Measurements on Liquid Resins and Curing Agents from 10-200 MHz
Author
Snell, John B. ; Olyphant, Murray, Jr.
Author_Institution
Industrial Specialties Division, the 3M Company, St. Paul., Minn. 55101
Issue
2
fYear
1975
fDate
6/1/1975 12:00:00 AM
Firstpage
54
Lastpage
57
Abstract
The goal was to develop a simple method for determining the dependence of dielectric constant and loss tangent on frequency in the range 10-200 MHz for a number of dielectrically lossy liquid resins. A test cell was devised which could be used with an available Hewlett-Packard RX meter. The calculations were worked out based on a calibration of cell constants and series inductance determined with five standard liquids. Data for five commercial resins and four curing agents are given. The method provides 5-percent or better accuracy up to 200 MHz.
Keywords
Calibration; Curing; Dielectric constant; Dielectric liquids; Dielectric losses; Dielectric measurements; Frequency; Inductance; Resins; Testing;