Title :
Design of coaxial-cable pulse transformers
Author :
Dollinger, Richard E. ; Moll, Douglas A. ; Smith, David L.
Author_Institution :
State University of New York at Buffalo, Amherst, NY
fDate :
10/1/1979 12:00:00 AM
Abstract :
Coaxial-cable pulse transformers with good high-frequency response (30-ns rise time) and excellent high-voltage interwinding insulation (≲300 kV primary to secondary) were designed, built, and tested. They have the advantage that the open-circuit transformation ratio is unaffected by the thickness of the interwinding insulation, and good coupling is maintained with step-up designs. An equivalent circuit was developed, involving two coupling coefficients, which predicted the measured results with reasonable accuracy. Values of primary, secondary, and leakage inductances were 1.4, 2.2, and 0.8 µH, respectively.
Keywords :
Coaxial components; Conductors; Couplings; Impedance; Inductance; Magnetic flux; Magnetic separation; Pulse generation; Pulse transformers; Testing;
Journal_Title :
Electron Devices, IEEE Transactions on
DOI :
10.1109/T-ED.1979.19648