DocumentCode
1066733
Title
Cryogenic System for DC Superconducting Power Transmission Line
Author
Hamabe, Makoto ; Sasaki, Atsushi ; Famakinwa, Tosin S. ; Ninomiya, Akira ; Ishiguro, Yasuhide ; Yamaguchi, Satarou
Author_Institution
Chubu Univ., Kasugai
Volume
17
Issue
2
fYear
2007
fDate
6/1/2007 12:00:00 AM
Firstpage
1722
Lastpage
1725
Abstract
Due to the recent developments of the electric power devices and the HTS power cables, DC superconducting power transmission system is considered to be practical. As one of the R & D issues of the DC superconducting power transmission system, we measured the radiation heat of the thermally-isolated stainless steel pipes with different surfaces. As the result, one sheet of aluminum foil pasted on the inner pipe surface reduced the heat radiation to 1.98 m/W between LN2 and the room temperature of 300 K.
Keywords
heat radiation; pipes; stainless steel; superconducting cables; DC superconducting power transmission line; HTS power cables; cryogenic system; heat radiation; thermally-isolated stainless steel pipes; Cryogenics; High temperature superconductors; Power cables; Power measurement; Power transmission; Power transmission lines; Steel; Superconducting cables; Superconducting transmission lines; Transmission line measurements; Cryogenics; DC superconducting power cable; radiation shield;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2007.898335
Filename
4277429
Link To Document