• DocumentCode
    1067017
  • Title

    Ultrasonic tracking of acoustic radiation force-induced displacements in homogeneous media

  • Author

    Palmeri, Mark L. ; McAleavey, Stephen A. ; Trahey, Gregg E. ; Nightingale, Kathryn R.

  • Author_Institution
    Student Member; Department of Biomedical Engineering, Duke University, Durham, NC 27706
  • Volume
    53
  • Issue
    7
  • fYear
    2006
  • fDate
    7/1/2006 12:00:00 AM
  • Firstpage
    1300
  • Lastpage
    1313
  • Abstract
    The use of ultrasonic methods to track the tissue deformation generated by acoustic radiation force is subject to jitter and displacement underestimation errors, with displacement underestimation being primarily caused by lateral and elevation shearing within the point spread function (PSF) of the ultrasonic beam. Models have been developed using finite element methods and Field II, a linear acoustic field simulation package, to study the impact of focal configuration, tracking frequency, and material properties on the accuracy of ultrasonically tracking the tissue deformation generated by acoustic radiation force excitations. These models demonstrate that lateral and elevation shearing underneath the PSF of the tracking beam leads to displacement underestimation in the focal zone. Displacement underestimation can be reduced by using tracking beams that are narrower than the spatial extent of the displacement fields. Displacement underestimation and jitter decrease with time after excitation as shear wave propagation away from the region of excitation reduces shearing in the lateral and elevation dimensions. The use of higher tracking frequencies in broadband transducers, along with 2D focusing in the elevation dimension, will reduce jitter and improve displacement tracking accuracy. Relative displacement underestimation remains constant as a function of applied force, whereas jitter increases with applied force. Underdeveloped speckle (SNR < 1.91) leads to greater levels of jitter and peak displacement underestimation. Axial shearing is minimal over the tracking kernel lengths used in acoustic radiation force impulse imaging and thus does not impact displacement tracking.
  • Keywords
    Acoustic beams; Acoustics; Finite element methods; Force; Imaging; Jitter; Shearing;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2006.1665078
  • Filename
    1665078