DocumentCode :
1067255
Title :
Performance of CdZnTe coplanar-grid gamma-ray detectors
Author :
Luke, P.N. ; Eissler, E.E.
Author_Institution :
Lawrence Berkeley Nat. Lab., CA, USA
Volume :
43
Issue :
3
fYear :
1996
fDate :
6/1/1996 12:00:00 AM
Firstpage :
1481
Lastpage :
1486
Abstract :
The spectral performance of coplanar grid detectors using currently available CdZnTe materials is examined theoretically and experimentally. Calculated spectral response based on the typical carrier mobility-lifetime products of current CdZnTe materials shows that energy resolution close to the charge-statistics limit can be achieved. Charge transport nonuniformity, which may limit the spectral performance of present detectors, is studied using alpha particle scanning
Keywords :
carrier lifetime; carrier mobility; gamma-ray detection; semiconductor counters; CdZnTe; CdZnTe coplanar-grid gamma-ray detectors; alpha particle; carrier lifetime; carrier mobility; charge transport nonuniformity; charge-statistics limit; coplanar grid detectors; energy resolution; performance; Charge carriers; Crystals; Degradation; Electrodes; Electrons; Energy resolution; Gamma ray detection; Gamma ray detectors; Induction generators; Radiation detectors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.507088
Filename :
507088
Link To Document :