• DocumentCode
    1067387
  • Title

    Palm-size low-level neutron sensor for radiation monitoring

  • Author

    Aryaeinejad, R. ; Dardenne, Y.X. ; Cole, J.D. ; Caffrey, A.J.

  • Author_Institution
    Idaho Nat. Eng. Lab., Idaho Falls, ID, USA
  • Volume
    43
  • Issue
    3
  • fYear
    1996
  • fDate
    6/1/1996 12:00:00 AM
  • Firstpage
    1539
  • Lastpage
    1543
  • Abstract
    We have developed a new technique for the detection of neutrons in the presence of a high gamma-ray background. This was accomplished by using two lithium-loaded glass scintillators (6Li/7Li) in combination. The neutron capture reaction in 6Li has a very high Q-value which means better discrimination against gamma-ray background. The 7Li detector, on the other hand, is neutron insensitive and was used to measure separately the gamma contribution in a mixed neutron-gamma field. By subtracting this gamma contribution from the 6Li data, which is sensitive to both gamma rays and neutrons, one can obtain the pure neutron counts
  • Keywords
    lithium; neutron detection; radiation monitoring; solid scintillation detectors; 6Li; 7Li; Li; Li-loaded glass scintillators; Q-value; high gamma-ray background; mixed neutron-gamma field; neutron capture reaction; neutron detection; palm-size low-level neutron sensor; radiation monitoring; Containers; Fuel storage; Gamma ray detection; Gamma ray detectors; Gamma rays; Glass; Material storage; Neutrons; Radiation monitoring; Radioactive waste;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.507099
  • Filename
    507099