Title : 
Electrical Performance of Oven-Dried XLPE Cable
         
        
        
            Author_Institution : 
Canada Wire and Cable Ltd., Toronto, Ontario, Canada
         
        
        
        
        
        
            Abstract : 
Accelerated aging tests conducted on miniature XLPE insulated cable have demonstrated that the oven-drying of steam-cuted XLPE cable insulation at 70°C does not impart any improvement in the initial breakdown voltage or in long-term electrical performance of the insulation over the as-received XLPE samples. Therefore, the oven-drying of steam-cured XLPE cable at 70°C is not considered as an effective method of improving cable quality.
         
        
            Keywords : 
Aging; Breakdown voltage; Cable insulation; Dielectrics and electrical insulation; Insulation testing; Moisture; Ovens; Temperature; Trees - insulation; Wire;
         
        
        
            Journal_Title : 
Electrical Insulation, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TEI.1978.298105