DocumentCode
1068008
Title
Short-term stability of laser-pumped rubidium gas cell frequency standard
Author
Saburi, Y. ; Koga, Yohei ; Kinugawa, S. ; Imamura, Takashi ; Suga, H. ; Ohuchi, Y.
Author_Institution
Res. Lab., Anritsu Corp., Kanagawa
Volume
30
Issue
8
fYear
1994
fDate
4/14/1994 12:00:00 AM
Firstpage
633
Lastpage
635
Abstract
The authors examine the influence of the light-shift effect on the frequency stability of a laser-pumped Rb gas cell standard for averaging time up to 104 s. The measured stability at the flicker floor is 7×10-14 for averaging times from 200 to 5000 s, providing that the laser frequency is properly set at the optical resonance frequency, and correcting for the variation of atmospheric pressure
Keywords
atomic clocks; frequency measurement; frequency stability; measurement standards; optical pumping; rubidium; 200 to 5000 s; Rb; atmospheric pressure variation correction; averaging time; flicker floor stability; frequency stability; frequency standard; laser-pumped Rb gas cell standard; light-shift effect; offset lock laser system; optical resonance frequency; short-term stability;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19940461
Filename
280651
Link To Document