The performance of the DELPHI Hadron Calorimeter at LEP
Author :
Ajinenko, I. ; Beloous, K. ; Chudoba, J. ; Czellar, S. ; Herr, H. ; Jouravlev, N. ; Khovansky, N. ; Kluit, P. ; Zrumstein, Z. ; Kurvinen, K. ; Lapin, V. ; Leitner, R. ; Masik, J. ; Olchevski, A. ; Ridky, J. ; Sedykh, Yu. ; Sicho, P. ; Smirnova, O. ; Solov
Author_Institution :
Inst. for High Energy Phys., Protvino, Russia
Volume :
43
Issue :
3
fYear :
1996
fDate :
6/1/1996 12:00:00 AM
Firstpage :
1751
Lastpage :
1756
Abstract :
The DELPHI Hadron Calorimeter was conceived more than ten years ago, as an instrument to measure the energy of hadrons and hadronic jets from e+e-collisions at the CERN collider LEP. In addition it was expected to provide a certain degree of discrimination between pions and muons. The detector is a rather simple and relatively inexpensive device consisting of around 20,000 limited streamer plastic tubes, with inductive pad read-out, embedded in the iron yoke of the 1.2 T DELPHI magnet. Its depth is at minimum 6.6 nuclear interaction lengths. The electronics necessary for the pad readout was designed to have an adequate performance for a reasonable cost. This detector has proved over six years of operation to have an entirely satisfactory performance and great reliability; for example less than 1% of the streamer tubes have failed and electronic problems remain at the per mil level. During the past two years an improvement programme has been under way. It has been found possible to use the streamer tubes as strips, hence giving better granularity and particle tracking, by reading out the cathode of individual tubes. The constraints on this were considerable because of the inaccessibility of the detectors in the magnet yoke. However a cheap and feasible solution has been found. The cathode readout leads to an improved energy resolution, better μ identification, a better π/μ separation and to possibilities of neutral particle separation. The simultaneous anode read-out of several planes of the endcaps of the detector will provide a fast trigger in the forward/backward direction which is an important improvement for LEP200. On the barrel the system will provide a cosmic trigger which is very useful for calibration as counting rates at LEP200 will be very low
Keywords :
calorimeters; meson detection; muon detection; position sensitive particle detectors; solid-state nuclear track detectors; streamer chambers; DELPHI Hadron Calorimeter; calibration; cosmic ray trigger; electronics; energy resolution; granularity; inductive pad read-out; muon identification; neutral particle separation; particle tracking; pion/muon separation; plastic streamer tubes; reliability; Cathodes; Detectors; Energy measurement; Instruments; Iron; Magnetic devices; Magnetic separation; Mesons; Nuclear electronics; Plastics;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.507216
Filename :
507216
Link To Document :
بازگشت