• DocumentCode
    1071238
  • Title

    Multi-Stress Endurance Tests on High-Voltage Motor Insulations, With Equal Acceleration Of Each Stress

  • Author

    Paloniemi, Paavo

  • Author_Institution
    Oy Strömberg Ab Helsinki, Finland
  • Issue
    3
  • fYear
    1982
  • fDate
    6/1/1982 12:00:00 AM
  • Firstpage
    253
  • Lastpage
    261
  • Abstract
    An ageing test was performed on two high-voltage motor insulation systems using three principal ageing stresses: temperature, electric field, and mechanical stress. An equal acceleration of each stress was used with the goal of an ageing process identical with that at service conditions. For the determination of the true acceleration factor a parallel ¿ageing¿ test at service conditions was run, up to so long testing times that changes in characteristic properties (flexural modulus, tan¿, and capacitance) could be determined. Humidity tests and high-voltage withstand tests were also performed after each ageing cycle. The observed acceleration factor for both systems was lower than predicted. In one of the systems the changes in characteristic properties were measurable and of the same type at both test conditions, so that the test acceleration could be evaluated reliably. Both systems show good class F performance connected with appropriately defined severe service conditions.
  • Keywords
    Accelerated aging; Capacitance; Dielectrics and electrical insulation; Humidity; Insulation testing; Life estimation; Performance evaluation; Stress; System testing; Temperature;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/TEI.1982.298464
  • Filename
    4080957