DocumentCode :
1071601
Title :
Rotating permanent magnetic fields exposure system for in vitro study
Author :
Song, Tao ; Wang, Zheng ; Zhao, Dexi ; Zhu, Qingzuo ; Huo, Xiaolin ; Xiao, Liye
Author_Institution :
Inst. of Electr. Eng., Chinese Acad. Sci., Beijing, China
Volume :
14
Issue :
2
fYear :
2004
fDate :
6/1/2004 12:00:00 AM
Firstpage :
1643
Lastpage :
1646
Abstract :
For the bioeffect study of the rotating magnetic fields, a permanent magnet of two layer magic rings driven by a motor was designed to produce a rotating magnetic field with tunable frequency (0-10 Hz) and tunable magnetic flux density (4-300 mT). In the design a simple 3D computing method was adopted to do the optimization. The actual results proved the efficiency of the method. The finished magnet fully satisfied the requirements of the bioelectromagnetic study.
Keywords :
biomagnetism; biomedical MRI; magnetic flux; magnetic multilayers; magnetoelectric effects; permanent magnets; superconducting magnets; 0 to 10 Hz; 3D computing method; 4 mT to 300 mT; bioeffect study; bioelectromagnetic study; in vitro study; magic rings; motor; permanent magnet; permanent magnetic fields exposure system; rotating magnetic fields; tunable frequency; tunable magnetic flux density; Coils; Frequency; In vitro; Magnetic devices; Magnetic fields; Magnetic flux; Magnetic flux density; Permanent magnet motors; Permanent magnets; Superconducting magnets; Flux density; magic ring; optimization; rotating permanent magnet;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2004.831024
Filename :
1325119
Link To Document :
بازگشت