• DocumentCode
    1071601
  • Title

    Rotating permanent magnetic fields exposure system for in vitro study

  • Author

    Song, Tao ; Wang, Zheng ; Zhao, Dexi ; Zhu, Qingzuo ; Huo, Xiaolin ; Xiao, Liye

  • Author_Institution
    Inst. of Electr. Eng., Chinese Acad. Sci., Beijing, China
  • Volume
    14
  • Issue
    2
  • fYear
    2004
  • fDate
    6/1/2004 12:00:00 AM
  • Firstpage
    1643
  • Lastpage
    1646
  • Abstract
    For the bioeffect study of the rotating magnetic fields, a permanent magnet of two layer magic rings driven by a motor was designed to produce a rotating magnetic field with tunable frequency (0-10 Hz) and tunable magnetic flux density (4-300 mT). In the design a simple 3D computing method was adopted to do the optimization. The actual results proved the efficiency of the method. The finished magnet fully satisfied the requirements of the bioelectromagnetic study.
  • Keywords
    biomagnetism; biomedical MRI; magnetic flux; magnetic multilayers; magnetoelectric effects; permanent magnets; superconducting magnets; 0 to 10 Hz; 3D computing method; 4 mT to 300 mT; bioeffect study; bioelectromagnetic study; in vitro study; magic rings; motor; permanent magnet; permanent magnetic fields exposure system; rotating magnetic fields; tunable frequency; tunable magnetic flux density; Coils; Frequency; In vitro; Magnetic devices; Magnetic fields; Magnetic flux; Magnetic flux density; Permanent magnet motors; Permanent magnets; Superconducting magnets; Flux density; magic ring; optimization; rotating permanent magnet;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2004.831024
  • Filename
    1325119