DocumentCode :
1071687
Title :
Successful Performance of the High Current Arc Ignition Test
Author :
Middendorf, W.H.
Author_Institution :
Dept. of Electrical and Computer Engineering University of Cincinnati
Issue :
5
fYear :
1982
Firstpage :
429
Lastpage :
433
Abstract :
The paper reports on the unexpected arcing phenomenon which takes place occasionally during the High Current Arc Ignition test. It also can be made to occur consistently by skillful placement of the electrodes. This will result in ignition with the smallest number of arcs. The differences in setting the electrodes is thought to be the major cause of inconsistent results among laboratories.
Keywords :
Circuits; Conducting materials; Dielectrics and electrical insulation; Electrodes; Ignition; Laboratories; Polymers; Reproducibility of results; Safety; Testing;