• DocumentCode
    1072283
  • Title

    Computer simulation of the helix traveling-wave amplifier with harmonic signals

  • Author

    MacGregor, Donald M.

  • Author_Institution
    Harris SAI, Inc., Ann Arbor, MI
  • Volume
    1
  • Issue
    6
  • fYear
    1980
  • fDate
    6/1/1980 12:00:00 AM
  • Firstpage
    104
  • Lastpage
    106
  • Abstract
    Both fundamental and second-harmonic output powers have been computed with an axially symmetric three-dimensional model of a helix traveling-wave amplifier. They agree reasonably well with measurements. For three beam power levels, the computed transfer curves show RF drive powers consistently about 3 dB below the measured powers and saturated output powers about 2 dB below the measured values. Inaccuracies in the assumed initial beam radius, density and velocity may have caused these differences. Suppressing the second harmonic raises the computed fundamental output power by 3 dB. The model accurately reproduces a measured 11 dB dip in the second harmonic as the fundamental signal saturates.
  • Keywords
    Computer simulation; Equations; Power amplifiers; Power generation; Power measurement; Power transmission lines; RF signals; Radio frequency; Radiofrequency amplifiers; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electron Device Letters, IEEE
  • Publisher
    ieee
  • ISSN
    0741-3106
  • Type

    jour

  • DOI
    10.1109/EDL.1980.25247
  • Filename
    1481109