Title :
Computer simulation of the helix traveling-wave amplifier with harmonic signals
Author :
MacGregor, Donald M.
Author_Institution :
Harris SAI, Inc., Ann Arbor, MI
fDate :
6/1/1980 12:00:00 AM
Abstract :
Both fundamental and second-harmonic output powers have been computed with an axially symmetric three-dimensional model of a helix traveling-wave amplifier. They agree reasonably well with measurements. For three beam power levels, the computed transfer curves show RF drive powers consistently about 3 dB below the measured powers and saturated output powers about 2 dB below the measured values. Inaccuracies in the assumed initial beam radius, density and velocity may have caused these differences. Suppressing the second harmonic raises the computed fundamental output power by 3 dB. The model accurately reproduces a measured 11 dB dip in the second harmonic as the fundamental signal saturates.
Keywords :
Computer simulation; Equations; Power amplifiers; Power generation; Power measurement; Power transmission lines; RF signals; Radio frequency; Radiofrequency amplifiers; Voltage;
Journal_Title :
Electron Device Letters, IEEE
DOI :
10.1109/EDL.1980.25247