DocumentCode
1072283
Title
Computer simulation of the helix traveling-wave amplifier with harmonic signals
Author
MacGregor, Donald M.
Author_Institution
Harris SAI, Inc., Ann Arbor, MI
Volume
1
Issue
6
fYear
1980
fDate
6/1/1980 12:00:00 AM
Firstpage
104
Lastpage
106
Abstract
Both fundamental and second-harmonic output powers have been computed with an axially symmetric three-dimensional model of a helix traveling-wave amplifier. They agree reasonably well with measurements. For three beam power levels, the computed transfer curves show RF drive powers consistently about 3 dB below the measured powers and saturated output powers about 2 dB below the measured values. Inaccuracies in the assumed initial beam radius, density and velocity may have caused these differences. Suppressing the second harmonic raises the computed fundamental output power by 3 dB. The model accurately reproduces a measured 11 dB dip in the second harmonic as the fundamental signal saturates.
Keywords
Computer simulation; Equations; Power amplifiers; Power generation; Power measurement; Power transmission lines; RF signals; Radio frequency; Radiofrequency amplifiers; Voltage;
fLanguage
English
Journal_Title
Electron Device Letters, IEEE
Publisher
ieee
ISSN
0741-3106
Type
jour
DOI
10.1109/EDL.1980.25247
Filename
1481109