DocumentCode :
1072667
Title :
Electrostatic Deflectors for Luminosity Measurements at the Cern pp Collider
Author :
Bonvin, R. ; Dubois, R. ; Garrel, N. ; Guinand, R. ; Kalbreier, W. ; Kissler, K.H.
Author_Institution :
SPS Division CERN Geneva, Switzerland
Issue :
3
fYear :
1983
fDate :
6/1/1983 12:00:00 AM
Firstpage :
322
Lastpage :
324
Abstract :
Electrostatic deflectors are used in the CERN SPS Collider to separate the orbits of protons and antiprotons. The total installation comprises 4 tanks, 3 m long each, with a vacuum of 10-8 Pa after baking. The operating electric field is 50 kV/cm across a gap of 4 cm, between 3 m long titanium electrodes; the spark rate does not exceed 2 per 24 hours. The construction, the HV circuit, and the performances of the separators are described in this paper.
Keywords :
Circuits; Electric breakdown; Electrodes; Electrostatic measurements; Extraterrestrial measurements; Protons; Resistors; Sparks; Structural beams; Titanium;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/TEI.1983.298620
Filename :
4081106
Link To Document :
بازگشت