Title :
Spatial encoding using a code division technique for fast ultrasound imaging
Author :
Gran, F. ; Jensen, J.A.
Author_Institution :
Tech. Univ. of Denmark, Lyngby
fDate :
1/1/2008 12:00:00 AM
Abstract :
This paper describes a method for spatial encoding in synthetic transmit aperture ultrasound imaging. This allows several ultrasonic sources to be active simultaneously. The method is based on transmitting pseudorandom sequences to spatially encode the transmitters. The data can be decoded after only one transmission using the knowledge of the transmitted code sequences as opposed to other spatial encoding techniques, such as Hadamard or Golay encoding. This makes the method less sensitive to motion, and data can be acquired using fewer transmissions. The aim of this paper is to analyze the underlying theory and to test the feasibility in a physical system. The method has been evaluated in simulations using Field II in which the point-spread functions were simulated for different depths for a 7 MHz linear array transducer. A signal-to-noise ratio (SNR) simulation also was included in the study in which an improvement in SNR of ~1.5 dB was attained compared to the standard synthetic transmit aperture (STA) firing scheme. Considering the amount of energy transmitted, this value is low. A plausible explanation is given that is verified in simulation. The method also was tested in an experimental ultrasound scanner and compared to a synthetic transmit aperture ultrasound imaging scheme using a sinusoidal excitation. The performance of the proposed method was comparable to the reference with respect to axial and lateral resolution, but it displayed poorer contrast with sidelobe levels at ~ - 40 dB compared to the mainlobe.
Keywords :
image coding; ultrasonic imaging; Field II; code division technique; fast ultrasound imaging; frequency 7 MHz; linear array transducer; point-spread functions; pseudorandom sequences; signal-to-noise ratio simulation; sinusoidal excitation; spatial encoding; synthetic transmit aperture firing scheme; synthetic transmit aperture ultrasound imaging; transmitted code sequences; ultrasonic sources; ultrasound scanner; Decoding; Encoding; Error correction; Error correction codes; Random sequences; Signal to noise ratio; System testing; Transducers; Transmitters; Ultrasonic imaging; Algorithms; Data Compression; Image Enhancement; Image Interpretation, Computer-Assisted; Numerical Analysis, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Ultrasonography;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2008.613