    Broadband ultrasound attenuation in the calcaneal region: a comparative study of single-position versus scanning systems

  • Author

    Maia, Joaquim M. ; Costa, Eduardo T. ; Neto, João F Marques ; Button, Vera L S N

  • Author_Institution
    Fed. Univ. of Technol., Curitiba
  • Volume
    55
  • Issue
    1
  • fYear
    2008
  • fDate
    1/1/2008 12:00:00 AM
  • Firstpage
    64
  • Lastpage
    73
  • Abstract
    This work describes a system developed to measure the broadband ultrasound attenuation (BUA) in the calcaneal region. The patient´s calcanei were inspected using a microcomputer-controlled X-Y axis displacement unit with two 500-kHz, central-frequency, ultrasound transducers. The transducers facing each other are submerged in a small water tank with a support for the patient´s foot between them. The system allows data to be collected from a single position or by scanning the calcaneal region to obtain a BUA map. Tests were carried out on 201 patients (110 using the single-position method, and 91 using the scanning method). The results were compared with those of densitometry tests performed using the dual energy X-ray absorptiometry (DEXA) technique (single position: r=0.50; P<0.0001; scanner: r=0.75; P<0.0001). It was concluded that the single position method is more susceptible to errors due to the difficulty in positioning the transducers relative to the calcaneus. The scanning method provides better results and can be used to screen patients before referring them for DEXA.
  • Keywords
    X-ray spectra; biomedical transducers; biomedical ultrasonics; bone; densitometry; ultrasonic transducers; broadband ultrasound attenuation; calcaneal region; central-frequency ultrasound transducers; densitometry tests; dual energy X-ray absorptiometry; microcomputer-controlled X-Y axis; scanning system; single-position system; Area measurement; Attenuation measurement; Biomedical engineering; Bones; Density measurement; Energy measurement; Osteoporosis; Ultrasonic imaging; Velocity measurement; Volume measurement; Adolescent; Adult; Aged; Aged, 80 and over; Calcaneus; Child; Densitometry; Equipment Design; Equipment Failure Analysis; Female; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Male; Middle Aged; Osteoporosis; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2008.617
  • Filename
    4454303