Title :
Peak shift in high density recording in particle media
Author :
Oehme, W.F. ; Basig, J. ; Mocker, G. ; Plunkenbuhler, R.
Author_Institution :
Lab. for Tech. Electron., Erlangen Univ., West Germany
fDate :
3/1/1988 12:00:00 AM
Abstract :
A single/double-density burst switching test pattern is used for the measurement of peak shift. Recording experiments with densities in the range of 1000 to 4000 flux reversals per millimeter have been carried out for oxide- and metal-particle media. The results are compared with linear superposition of isolated pulses. While at low densities the behavior is well approximated by linear superposition, the experiments unveil a rather uniform burst shift at higher densities. The effect of equalization is also shown.
Keywords :
magnetic recording; high density recording; metal-particle media; oxide-particle media; particle media; peak shift; switching test pattern; Disk recording; Electronic equipment testing; Laboratories; Magnetic heads; Magnetic materials; Magnetic recording; Polynomials; Shape measurement; Timing; Video recording;
Journal_Title :