DocumentCode :
1076878
Title :
Water Immersion Testing of Form-Wound Coil Insulation
Author :
Botts, John C. ; Wolford, Robert D.
Author_Institution :
Westinghouse Electric Corporation, East Pittsburgh, Pa. 15112
Issue :
3
fYear :
1969
Firstpage :
77
Lastpage :
82
Abstract :
Motors are today required to operate in more severe environments than formerly. This paper reports a study of suitable test methods for evaluating the ability of insulation systems to withstand moisture exposure as thermal aging progresses. A new motorette exposure cycle has been recommended to the IEEE Working Group on Sealed Insulation Systems of the Rotating Machinery Committee.
Keywords :
Acceleration; Chemicals; Coils; Degradation; Dielectrics and electrical insulation; Insulation testing; Machinery; Moisture; Stress; System testing;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/TEI.1969.299062
Filename :
4081563
Link To Document :
بازگشت