• DocumentCode
    1076970
  • Title

    Camera calibration: a quick and easy way to determine the scale factor

  • Author

    Penna, Michael A.

  • Author_Institution
    Dept. of Math. & Comput. Sci., Indiana-Purdue Univ., Indianapolis, IN, USA
  • Volume
    13
  • Issue
    12
  • fYear
    1991
  • fDate
    12/1/1991 12:00:00 AM
  • Firstpage
    1240
  • Lastpage
    1245
  • Abstract
    The author presents a quick and easy solution to the camera calibration problem of finding the scale factor that arises because of a difference between the scanning frequency of the camera sensor plane and the scanning frequency of the image capture board frame buffer. The method presented is based on the observation that the scale factor is related to the distortion in an image of a circle: this is a distortion that can easily be measured by considering the occluding boundary of a precisely fabricated sphere, such as a ball bearing. Implementation results are presented
  • Keywords
    calibration; cameras; image sensors; ball bearing; camera calibration; camera sensor plane; distortion; image capture board frame buffer; image sensors; occluding boundary; scale factor; scanning frequency; Ball bearings; Calibration; Cameras; Computer vision; Distortion measurement; Frequency; Image sensors; Lenses; Machine vision; Metrology;
  • fLanguage
    English
  • Journal_Title
    Pattern Analysis and Machine Intelligence, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0162-8828
  • Type

    jour

  • DOI
    10.1109/34.107007
  • Filename
    107007