Title :
New Silicone Rubber Insulation System for Turbine Generators
Author :
Galpern, Harold N. ; Brown, John M.
Author_Institution :
General Electric Company, West Lynn. Mass.
fDate :
3/1/1971 12:00:00 AM
Abstract :
A new composite polyester-glass reinforced silicone rubber/mica insulation system, designated Mycone¿, has been developed for high-voltage turbine generators. This system is capable of operating at Class F (155°C) temperatures, with a life expectancy comparable to that of a standard type modified asphaltmica insulation system operating at Class B (130°C) temperaturese. Use of the system will afford an increase in generator armature capability in the order of 15 percent. Although domestic industry standards do not yet include the operation of turbine-generator units above Class B (130°C) operating temperatures, many special situations exist where increased capability is of prime consideration.
Keywords :
Assembly systems; Breakdown voltage; Cooling; Dielectrics and electrical insulation; Rubber; Standards development; Technological innovation; Temperature; Trademarks; Turbines;
Journal_Title :
Electrical Insulation, IEEE Transactions on
DOI :
10.1109/TEI.1971.299130