Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction
Author :
Jakoby, Bjoern W. ; Bercier, Yanic ; Watson, Charles C. ; Bendriem, Bernard ; Townsend, David W.
Author_Institution :
Dept. of Mol. Imaging, Siemens Med. Solutions USA, Inc., Knoxville, TN
Volume :
56
Issue :
3
fYear :
2009
fDate :
6/1/2009 12:00:00 AM
Firstpage :
633
Lastpage :
639
Abstract :
A new combined lutetium oxyorthosilicate (LSO) PET/CT scanner with an extended axial field-of-view (FOV) of 21.8 cm has been developed (Biograph TruePoint PET/CT with TrueV; Siemens Molecular Imaging) and introduced into clinical practice. The scanner includes the recently announced point spread function (PSF) reconstruction algorithm. The PET components incorporate four rings of 48 detector blocks, 5.4 cm times 5.4 cm in cross-section. Each block comprises a 13 times 13 matrix of 4 times 4 times 20 mm3 elements. Data are acquired with a 4.5 ns coincidence time window and an energy window of 425-650 keV. The physical performance of the new scanner has been evaluated according to the recently revised National Electrical Manufacturers Association (NEMA) NU 2-2007 standard and the results have been compared with a previous PET/CT design that incorporates three rings of block detectors with an axial coverage of 16.2 cm (Biograph TruePoint PET/CT; Siemens Molecular Imaging). In addition to the phantom measurements, patient Noise Equivalent Count Rates (NECRs) have been estimated for a range of patients with different body weights (42-154 kg). The average spatial resolution is the same for both scanners: 4.4 mm (FWHM) and 5.0 mm (FWHM) at 1 cm and 10 cm respectively from the center of the transverse FOV. The scatter fractions of the Biograph TruePoint and Biograph TruePoint TrueV are comparable at 32%. Compared to the three ring design, the system sensitivity and peak NECR with smoothed randoms correction (1R) increase by 82% and 73%, respectively. The increase in sensitivity from the extended axial coverage of the Biograph TruePoint PET/CT with TrueV should allow a decrease in either scan time or injected dose without compromising diagnostic image quality. The contrast improvement with the PSF reconstruction potentially offers enhanced detectability for small lesions.
Keywords :
image scanners; medical image processing; positron emission tomography; Biograph TruePoint TrueV; NEMA NU 2-2007 standard; Siemens molecular imaging; computerised tomography scanners; diagnostic image quality; distance 16.2 cm; distance 21.8 cm; electron volt energy 425 keV to 650 keV; lutetium oxyorthosilicate; point spread function reconstruction algorithm; positron emission tomography scanners; size 20 mm; size 4 mm; size 5.4 cm; time 4.5 ns; Computed tomography; Detectors; Image reconstruction; Imaging phantoms; Manufacturing; Molecular imaging; Noise measurement; Positron emission tomography; Reconstruction algorithms; Spatial resolution; Extended FOV; NEMA measurements; PET/CT; PSF reconstruction;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2009.2015764
Filename :
5075946
Link To Document :
بازگشت