DocumentCode :
1078333
Title :
The Flashover Voltage of Polymethylmethacrylate in Vacuum under Direct, Alternating, and Surge Voltages of Various Front Durations
Author :
Grzybowski, S. ; Kuffel, E. ; C. Mcmath, J. P.
Author_Institution :
University of Manitoba, Winnipeg, Man., Canada. He is currently on leave from Politechnika, Poznanska, Poland
Issue :
4
fYear :
1972
Firstpage :
180
Lastpage :
185
Abstract :
This paper presents results on flashover voltages across insulation surfaces and on the rate of surface deterioration in a vacuum of 10-5 torr under direct, alternating, and surge voltages of front duration in the range from 1-600 ¿s. The insulation material used was polymethylmethacrylate (PMMA) of cylindrical shape fitted between uniform field electrodes. The measurements were carried out on insulator specimens 25 mm in diameter and 5, 10, and 20 mm in length.
Keywords :
Cables; Dielectrics and electrical insulation; Electrodes; Flashover; Frequency; Shape; Surges; Vacuum breakdown; Vacuum systems; Voltage;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/TEI.1972.299222
Filename :
4081726
Link To Document :
بازگشت