    Fast X-Ray Spectroscopy Using Si-Drift Detectors

  • Author

    Hansen, Karsten ; Reckleben, Christian ; Diehl, Inge ; Klär, Helmut ; Welter, Edmund

  • Author_Institution
    Deutsches Elektronen-Synchrotron (DESY), Hamburg
  • Volume
    56
  • Issue
    3
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    1666
  • Lastpage
    1670
  • Abstract
    Fast counting applications with energy discrimination like X-ray absorption spectroscopy require an energy resolution of some hundred eV even at highest count rates and ask for small form factors. The development, fabrication and test of a small number of 7-cell Si-drift detectors have been successfully finished at DESY fitting these claims with a good cost-versus-performance tradeoff. The monolithic 7-cell sensor chip and a corresponding readout chip are the key components of the sensor head. The module´s length and wrench size amounts to 21.2 and 1.6 cm, respectively. Its active area is ~ 7 times 7 mm2 and main energy range is 2.5 to 18 keV. Between ~ 5 and 20 keV the nonlinearity in a six-modules setup is well within plusmn 2% and plusmn 0.5% when uncompensated and compensated, respectively. The Cu-Kalpha line width is (271 plusmn 46) eV when operated at 10degC. With the best SDD chip we achieved (223 plusmn 7) eV at 10degC and (294 plusmn 10) eV at 24degC . By selection of the three best devices the spectral resolution reaches 400 and 600 eV at 10degC and a sum-count rate of 3.3middot106 s-1 and 6.7middot106 s-1, respectively. XAFS measurements have shown that the peak shift and line-width variations remain below 5 eV and 17 eV, respectively.
  • Keywords
    X-ray absorption spectra; X-ray spectroscopy; nuclear electronics; readout electronics; silicon radiation detectors; spectral line breadth; 7-cell silicon-drift detectors; Cu-Kalpha line width; DESY; SDD chip; X-ray absorption spectroscopy; XAFS measurements; electron volt energy 2.5 keV to 18 keV; electron volt energy 400 eV; electron volt energy 600 eV; energy discrimination; fast X-ray spectroscopy; fast counting applications; monolithic 7-cell sensor chip; readout chip; size 1.6 cm; size 21.2 cm; spectral resolution; temperature 10 C; temperature 24 C; Chemical elements; Electromagnetic wave absorption; Energy resolution; Fabrication; Fluorescence; Radiation detectors; Spectroscopy; Testing; X-ray detection; X-ray detectors; Silicon-drift detector; X-ray absorption spectroscopy; X-ray standing waves; spectral resolution;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2009.2015947
  • Filename
    5076017