Title :
Characterisation Results From an AGATA Prototype Detector
Author :
Dimmock, Matthew Richard ; Boston, Andrew John ; Boston, Helen Claire ; Cresswell, John Ronald ; Nelson, Laura ; Nolan, Paul J. ; Unsworth, Carl ; Lazarus, Ian H. ; Simpson, John
Author_Institution :
Oliver Lodge Lab., Univ. of Liverpool, Liverpool
fDate :
6/1/2009 12:00:00 AM
Abstract :
An Advanced GAmma Tracking Array (AGATA) symmetric prototype high purity Germanium (HPGe) detector has been tested. The detector was illuminated with a 1 mm collimated beam of 137Cs (662 keV) gamma rays. The beam was raster scanned across the front and sides of the detector and the charge sensitive preamplifier output pulse shapes from all 37 channels (36 segments plus the centre contact) were digitised and stored for off-line analysis. Rise time and image charge asymmetry magnitudes were measured as a function of interaction position to study the charge transport properties through the crystal volume. These parameters were then utilised as a calibrated look up table with which in-beam data was analysed and Doppler corrected. An average position resolution of approximately 9 mm (FWHM) was achieved with a crude analysis.
Keywords :
calibration; gamma-ray detection; germanium radiation detectors; particle tracks; preamplifiers; prototypes; 137Cs gamma ray; AGATA prototype detector; HPGe detector; advanced gamma tracking array symmetric prototype; calibration; charge sensitive preamplifier output pulse shape; high purity germanium detector; image charge asymmetry magnitude; Collimators; Gamma ray detection; Gamma ray detectors; Gamma rays; Germanium; Preamplifiers; Prototypes; Pulse shaping methods; Sensor arrays; Testing; Charge collection; gamma-ray spectroscopy; germanium detectors; signal analysis; tracking detectors;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2009.2019103