DocumentCode :
1079358
Title :
The Atomistic Simulation of Thermal Diffusion and Coulomb Drift in Semiconductor Detectors
Author :
Jeong, Manhee ; Hammig, Mark D.
Author_Institution :
Dept. of Nucl. Eng. & Radiol. Sci., Univ. of Michigan, Ann Arbor, MI
Volume :
56
Issue :
3
fYear :
2009
fDate :
6/1/2009 12:00:00 AM
Firstpage :
1364
Lastpage :
1371
Abstract :
In order to enhance the imaging resolution of gamma cameras over standard Compton camera and coded aperture designs, one can add momentum information to the kinematics by tracking the recoil electrons that result from gamma-ray interactions. The initial direction of the recoil electron can be discerned from its meandering trajectory, as measured via the initial electron-hole charges´ spatial distribution, which itself is extracted by measuring the induced current signal on the bounding electrodes of the detector. In principle, the extraction of the recoil electron direction is ultimately limited by those stochastic effects that significantly contribute to the charge motion; most notably, thermal diffusion, although for existing systems, electronic noise can contribute or even dominate the position uncertainty. Nevertheless, we neglect the effects of electronic noise in this paper in order to gauge the intrinsic uncertainty in the charges´ positions. We model diffusion using two techniques: one found in the literature and based on the diffusion coefficient, the other based on the underlying physics in which the probability density function describing the random thermal motion is sampled to determine the random contribution to each charge´s motion, which depends on its drift state as well as the surrounding crystallographic environment. As is shown, the effect of diffusion is always significant, but its effect can be mitigated if the charges drift with alacrity. Coulomb drift, which refers to the dynamic charge motion due to the electromagnetic forces of the space charge created during the radiation event, is usually neglected; however, it can also be important for highly ionizing particles. We thus quantify the effect of Coulomb drift and suggest methods by which its impact can be extracted from the overall charge-track reconstruction.
Keywords :
Compton effect; electromagnetic forces; gamma-ray apparatus; particle tracks; probability; random processes; silicon radiation detectors; space charge; stochastic processes; thermal diffusion; Coulomb drift; atomistic simulation; bounding electrodes; charge-track reconstruction; dynamic charge motion; electron-hole charge; electronic noise; gamma cameras; gamma-ray interactions; imaging resolution; meandering trajectory; momentum information; probability density function; random thermal motion; recoil electrons; semiconductor detectors; silicon detector; standard Compton camera; stochastic effects; thermal diffusion; Apertures; Cameras; Code standards; Current measurement; Detectors; Electrons; Image resolution; Optical imaging; Semiconductor device noise; Uncertainty; Coulomb drift; Monte Carlo modeling; semiconductor detectors; thermal diffusion;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2009.2021426
Filename :
5076041
Link To Document :
بازگشت