DocumentCode :
1079962
Title :
Ion Impact Detection and Micromapping With a SDRAM for IEEM Diagnostics and Applications
Author :
Bertazzoni, Stefano ; Bisello, Dario ; Giubilato, Piero ; Kaminsky, Alexander ; Mattiazzo, Serena ; Mongiardo, Lorenzo ; Pantano, Devis ; Rando, Riccardo ; Salmeri, Marcello ; Salsano, Adelio ; Silvestrin, Luca ; Tessaro, Mario ; Wyss, Jeffery
Author_Institution :
Dept. of Electron. Eng., Univ. of "Tor Vergata", Rome
Volume :
56
Issue :
3
fYear :
2009
fDate :
6/1/2009 12:00:00 AM
Firstpage :
853
Lastpage :
857
Abstract :
Ion electron emission microscopy (IEEM) can provide an alternative approach to microbeams for micrometric characterization of the sensitivity map to single event effects (SEE) of an electronic device. In IEEM technique, a broad (not focused) ion beam is sent onto the device under test (DUT). Secondary electrons emitted by the target surface during each ion impact are collected and focused by a system of electrostatic lenses and finally imaged by a high-rate and high-resolution position detector. We will report on the IEEM working at the SIRAD irradiation facility located at the 15 MV Tandem of INFN Legnaro National Laboratories. To estimate the IEEM resolution, a SDRAM is a good candidate to be used as a reference target, thanks to the micrometric feature size of the array of memory cells and the precise knowledge of their physical locations. Since an electronic device is not a good secondary electrons emitter, to ensure a copious and uniform emission of secondary electrons from the DUT, a very thin (100 nm) self-standing silicon nitride (Si3N4) membrane with a Au deposition (40 nm) is mounted on the top of the SDRAM. The Au/Si3N4 membrane and the underlying SDRAM are irradiated with a heavy ion beam. The physical map of ion impacts detected by the SDRAM is then compared with the one reconstructed by the IEEM in the same 500 ms time interval.
Keywords :
DRAM chips; electron emission; electron microscopy; electrostatic devices; ion beams; ion-surface impact; silicon compounds; IEEM diagnostics; INFN Legnaro National Laboratories; SDRAM; electronic device; high-resolution position detector; ion electron emission microscopy; ion impact detection; memory cells; micromapping; secondary electron emissions; silicon nitride; single event effects; size 400 nm; Biomembranes; Electron emission; Electron microscopy; Electrostatics; Focusing; Gold; Ion beams; Lenses; SDRAM; Testing; Ion electron emission microscopy; SDRAM; radiation effects; single event upset (SEU);
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2009.2020408
Filename :