DocumentCode :
1082671
Title :
A mean blood velocity statistic for the Doppler signal from a narrow ultrasound beam
Author :
Willink, Robin ; Evans, David H.
Author_Institution :
Div. of Med. Phys., Leicester Univ., UK
Volume :
41
Issue :
4
fYear :
1994
fDate :
4/1/1994 12:00:00 AM
Firstpage :
322
Lastpage :
331
Abstract :
An easily calculable statistic proportional to the instantaneous spatial mean blood velocity through a vessel cross section is derived from Doppler power spectral estimates for the case where the Doppler beam is assumed to be of negligible thickness compared to the vessel diameter. This is an alternative statistic to that derived where uniform insonation is assumed, an assumption thought to be poorer in many real cases. The main requirement is that the velocity profile is monotonic increasing from the vessel wall to the vessel center. Errors in each statistic are compared for a variety of true beam dimensions, using a variety of velocity profiles, and the new statistic is shown to incur less error for Gaussian beam response profiles with a standard deviation less than 0.4 of the vessel radius, or for rectangular response profiles with a width less than 0.65 of the vessel diameter. If an estimate can be made of the true beam dimensions and vessel diameter, a weighted sum of the two statistics can give a more accurate estimate of mean velocity. The case of a beam displaced from the center of the vessel is also considered, and errors are found to be less than 4% for a displacement of 20% of the vessel radius.
Keywords :
Doppler effect; biomedical measurement; biomedical ultrasonics; haemodynamics; ultrasonic velocity measurement; Doppler power spectral estimates; Doppler signal; Gaussian beam response profiles; beam dimensions; instantaneous spatial mean blood velocity; mean blood velocity statistic; medical measurement; monotonic velocity profile; narrow ultrasound beam; rectangular response profiles; uniform insonation; vessel cross section; vessel diameter; vessel radius; weighted sum; Biomedical imaging; Blood; Error analysis; Frequency estimation; Helium; Particle scattering; Shape; Statistics; Ultrasonic imaging; Ultrasonic variables measurement; Bias (Epidemiology); Blood Flow Velocity; Blood Volume; Carotid Arteries; Data Interpretation, Statistical; Models, Cardiovascular; Normal Distribution; Reproducibility of Results; Signal Processing, Computer-Assisted;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.284960
Filename :
284960
Link To Document :
بازگشت