DocumentCode :
1084575
Title :
CCD camera for dual-energy digital subtraction angiography
Author :
Molloi, Sabee ; Ersahin, Atila ; Qian, Yao-Jin
Author_Institution :
Dept. of Radiol. Sci., California Univ., Irvine, CA, USA
Volume :
14
Issue :
4
fYear :
1995
fDate :
12/1/1995 12:00:00 AM
Firstpage :
747
Lastpage :
752
Abstract :
A motion immune dual-energy subtraction technique in which X-ray tube voltage and beam filtration were switched at 30 Hz between 60 kVp (2.0 mm Al filter) and 120 kVp (2.00 mm Al+2.5 mm Cu filter) was previously reported. In this study the effects of camera lag on the dual-energy iodine signal is investigated. The temporal lag of the lead oxide vidicon tested reduced the dual-energy iodine signal by a factor of 2.3, as compared to a mode that included 4 scrub frames between low- and high-energy images, for an iodine phantom with thicknesses of 0-86.0 mg/cm2, imaged over a 15 cm thick Lucite phantom. On the other hand, the Charge-Coupled Device (CCD) camera has inherently no temporal lag and its versatile scanning characteristics make it near ideal for dual-energy DSA. The CCD camera eliminates the reduction of dual-energy iodine signal, since it does not mix low- and high-energy image data. Another benefit of the CCD camera is that the separation time between low and high-energy images is not limited to the frame period, as is the lead oxide vidicon; and as small as a 5-msec time difference is possible. The short time interval between low and high-energy images minimizes motion misregistration artifacts. Due to these advantages, the CCD camera significantly improves the utility of dual-energy DSA
Keywords :
CCD image sensors; angiocardiography; biomedical equipment; diagnostic radiography; 15 cm; 30 Hz; CCD camera; Charge-Coupled Device camera; Lucite phantom; X-ray tube voltage; beam filtration; camera lag; coronary angiography; dual-energy DSA; dual-energy digital subtraction angiography; dual-energy iodine signal; frame period; high-energy images; iodine phantom; lead oxide vidicon; low-energy images; motion immune dual-energy subtraction technique; scrub frames; temporal lag; versatile scanning characteristics; Angiography; Charge coupled devices; Charge-coupled image sensors; Digital cameras; Filters; Filtration; Imaging phantoms; Lead compounds; Subtraction techniques; Voltage;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.476115
Filename :
476115
Link To Document :
بازگشت