• DocumentCode
    1084612
  • Title

    Parallelized formulation of the maximum likelihood-expectation maximization algorithm for fine-grain message-passing architectures

  • Author

    Cruz-Rivera, J.L. ; Di Bella, E.V.R. ; Wills, D.S. ; Gaylord, T.K. ; Glytsis, E.N.

  • Author_Institution
    Microelectron. Res. Center, Georgia Inst. of Technol., Atlanta, GA, USA
  • Volume
    14
  • Issue
    4
  • fYear
    1995
  • fDate
    12/1/1995 12:00:00 AM
  • Firstpage
    758
  • Lastpage
    762
  • Abstract
    Recent architectural and technological advances have led to the feasibility of a new class of massively parallel processing systems based on a fine-grain, message-passing computational model. These machines provide a new alternative for the development of fast, cost-efficient Maximum Likelihood-Expectation Maximization (ML-EM) algorithmic formulations. As an important first step in determining the potential performance benefits to be gathered from such formulations, we have developed an ML-EM algorithm suitable for the high-communications, low-memory (HCLM) execution model supported by this new class of machines. Evaluation of this algorithm indicates a normalized least-square error comparable to, or better than, that obtained via a sequential ray-driven ML-EM formulation and an effective speedup in execution time (as determined via discrete-event simulation of the Pica multiprocessor system currently under development at the Georgia Institute of Technology) of well over two orders of magnitude compared to current ray-driven sequential ML-EM formulations on high-end workstations. Thus, the HCLM algorithmic formulation may provide ML-EM reconstructions within clinical time-frames
  • Keywords
    image reconstruction; maximum likelihood estimation; medical image processing; message passing; parallel architectures; positron emission tomography; single photon emission computed tomography; HCLM algorithmic formulation; ML-EM reconstructions; Pica multiprocessor system; Positron Emission Tomography; Single-Photon Emission Computed Tomography; clinical time-frames; discrete-event simulation; execution time; fast cost-efficient ML-EM algorithmic formulations; fine-grain message-passing architectures; high-communications low-memory execution model; massively parallel processing systems; maximum likelihood-expectation maximization algorithm; message-passing computational model; normalized least-square error; parallelized formulation; sequential ray-driven ML-EM formulation; Biomedical computing; Computational modeling; Computer architecture; Concurrent computing; Costs; Discrete event simulation; Image reconstruction; Parallel processing; Positron emission tomography; Workstations;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.476118
  • Filename
    476118