• DocumentCode
    1085177
  • Title

    In situ narrow-band calibration of an acoustic receiver

  • Author

    Teeter, James L.

  • Author_Institution
    Naval Undersea Center, San Diego, Calif.
  • Volume
    22
  • Issue
    1
  • fYear
    1974
  • fDate
    2/1/1974 12:00:00 AM
  • Firstpage
    56
  • Lastpage
    62
  • Abstract
    A technique for in situ narrow-band calibration of an acoustic receiver is described. Wide-band Gaussian noise is applied through a random acoustic channel to the receiver and a reference. The resultant output spectra are estimated via Welch´s method [1], and the unknown amplitude frequency response is estimated from the ratio of the two spectra. Statistical accuracies of the estimates are investigated. For a specified statistical accuracy, the estimate of the unknown amplitude frequency response is found to require the computation of only one-fourth as many discrete Fourier transforms (DFT´s) as the estimates of the two power spectra. That is, where N DFT´s are necessary to estimate the two power spectra with a specific accuracy, only N/4 DFT´s are needed to estimate, with the same accuracy, the ratio of the spectra.
  • Keywords
    Amplitude estimation; Calibration; Convolution; Discrete Fourier transforms; Frequency domain analysis; Frequency estimation; Frequency response; Narrowband; Sampling methods; Statistics;
  • fLanguage
    English
  • Journal_Title
    Acoustics, Speech and Signal Processing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0096-3518
  • Type

    jour

  • DOI
    10.1109/TASSP.1974.1162540
  • Filename