DocumentCode
1087808
Title
A New Critical Formula and Mathematical Model of Double-Tap Interphase Reactor in a Six-Phase Tap-Changer Diode Rectifier
Author
Qijun, Pan ; Weiming, Ma ; Dezhi, Liu ; Zhihua, Zhao ; Jin, Meng
Author_Institution
Res. Inst. of Power Electron. Technol., Naval Univ, Wuhan
Volume
54
Issue
1
fYear
2007
Firstpage
479
Lastpage
485
Abstract
This paper presents a new practical formula to calculate the critical value of interphase reactor (IPR) in a six-phase diode rectifier with tap-changer. In addition, a mathematical model of the double-tap IPR has been established by equivalent circuit method. Simulation and experimental results verify the validity of the formula and mathematical model. On the basis of the above achievements, a simple and effective approach is provided to design the IPR and to analyze the performance of the whole system
Keywords
diodes; equivalent circuits; on load tap changers; rectifying circuits; double-tap interphase reactor; equivalent circuit method; six-phase tap-changer diode rectifier; Bridge circuits; Circuit simulation; Diodes; Educational programs; Equivalent circuits; Inductors; Intellectual property; Mathematical model; Rectifiers; Voltage; Critical formula; interphase reactor; mathematical model; six-phase diode rectifier; tap-changer;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2006.888800
Filename
4084696