• DocumentCode
    1087808
  • Title

    A New Critical Formula and Mathematical Model of Double-Tap Interphase Reactor in a Six-Phase Tap-Changer Diode Rectifier

  • Author

    Qijun, Pan ; Weiming, Ma ; Dezhi, Liu ; Zhihua, Zhao ; Jin, Meng

  • Author_Institution
    Res. Inst. of Power Electron. Technol., Naval Univ, Wuhan
  • Volume
    54
  • Issue
    1
  • fYear
    2007
  • Firstpage
    479
  • Lastpage
    485
  • Abstract
    This paper presents a new practical formula to calculate the critical value of interphase reactor (IPR) in a six-phase diode rectifier with tap-changer. In addition, a mathematical model of the double-tap IPR has been established by equivalent circuit method. Simulation and experimental results verify the validity of the formula and mathematical model. On the basis of the above achievements, a simple and effective approach is provided to design the IPR and to analyze the performance of the whole system
  • Keywords
    diodes; equivalent circuits; on load tap changers; rectifying circuits; double-tap interphase reactor; equivalent circuit method; six-phase tap-changer diode rectifier; Bridge circuits; Circuit simulation; Diodes; Educational programs; Equivalent circuits; Inductors; Intellectual property; Mathematical model; Rectifiers; Voltage; Critical formula; interphase reactor; mathematical model; six-phase diode rectifier; tap-changer;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2006.888800
  • Filename
    4084696