A Haptic Feedback System for Lower-Limb Prostheses
Author
Fan, Richard E. ; Culjat, Martin O. ; King, Chih-Hung ; Franco, Miguel L. ; Boryk, Richard ; Bisley, James W. ; Dutson, Erik ; Grundfest, Warren S.
Author_Institution
Dept. of Biomed. Eng., California Univ., Los Angeles, CA
Volume
16
Issue
3
fYear
2008
fDate
6/1/2008 12:00:00 AM
Firstpage
270
Lastpage
277
Abstract
A haptic feedback system has been developed to provide sensory information to patients with lower-limb prostheses or peripheral neuropathy. Piezoresistive force sensors were mounted against four critical contact points of the foot to collect and relay force information to a system controller, which in turn drives four corresponding pneumatically controlled balloon actuators. The silicone-based balloon actuators were mounted on a cuff worn on the middle thigh, with skin contacts on the posterior, anterior, medial, and lateral surfaces of the thigh. Actuator characterization and human perceptual testing were performed to determine the effectiveness of the system in providing tactile stimuli. The actuators were determined to have a monotonic input pressure-vertical deflection response. Six normal subjects wearing the actuator cuff were able to differentiate inflation patterns, directional stimuli and discriminate between three force levels with 99.0%, 94.8%, and 94.4% accuracy, respectively. With force sensors attached to a shoe insole worn by an operator, subjects were able to correctly indicate the movements of the operator with 95.8% accuracy. These results suggest that the pneumatic haptic feedback system design is a viable method to provide sensory feedback for the lower limbs.
Keywords
biomedical transducers; feedback; handicapped aids; haptic interfaces; medical control systems; patient rehabilitation; pneumatic actuators; prosthetics; haptic feedback system; human perceptual testing; lower-limb prosthesis; monotonic input pressure-vertical deflection response; peripheral neuropathy; piezoresistive force sensors; pneumatically controlled balloon actuators; sensory feedback; silicone-based balloon actuators; skin contacts; Biomedical transducers; biomedical transducers; haptic feedback; lower-limb rehabilitation; prosthesis; sensory feedback; Equipment Design; Equipment Failure Analysis; Humans; Lower Extremity; Physical Stimulation; Prostheses and Implants; Touch; Transducers;
fLanguage
English
Journal_Title
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher
ieee
ISSN
1534-4320
Type
jour
DOI
10.1109/TNSRE.2008.920075
Filename
4463638
Link To Document