• DocumentCode
    1091147
  • Title

    Method for Determining Kinematic Parameters of the In Vivo Thumb Carpometacarpal Joint

  • Author

    Chang, Lillian Y. ; Pollard, Nancy S.

  • Author_Institution
    Robot. Inst. in the Sch. of Comput. Sci., Carnegie Mellon Univ., Pittsburgh, PA
  • Volume
    55
  • Issue
    7
  • fYear
    2008
  • fDate
    7/1/2008 12:00:00 AM
  • Firstpage
    1897
  • Lastpage
    1906
  • Abstract
    The mobility of the thumb carpometacarpal (CMC) joint is critical for functional grasping and manipulation tasks. We present an optimization technique for determining from surface marker measurements a subject-specific kinematic model of the in vivo CMC joint that is suitable for measuring mobility. Our anatomy-based cost metric scores a candidate joint model by the plausibility of the corresponding joint angle values and kinematic parameters rather than only the marker trajectory reconstruction error. The proposed method repeatably determines CMC joint models with anatomically-plausible directions for the two dominant rotational axes and a lesser range of motion (RoM) for the third rotational axis. We formulate a low-dimensional parameterization of the optimization domain by first solving for joint axis orientation variables that then constrain the search for the joint axis location variables. Individual CMC joint models were determined for 24 subjects. The directions of the flexion-extension (FE) axis and adduction-abduction (AA) axis deviated on average by 9deg and 22deg, respectively, from the mean axis direction. The average RoM for FE, AA, and pronation-supination (PS) joint angles were 76deg, 43deg, and 23deg for active CMC movement. The mean separation distance between the FE and AA axes was 4.6 mm, and the mean skew angle was 87deg from the positive flexion axis to the positive abduction axis.
  • Keywords
    biomechanics; bone; patient diagnosis; patient treatment; adduction-abduction axis; flexion-extension axis; grasping task; in vivo thumb carpometacarpal joint; joint angle values; joint axis orientation variable; joint mobility; kinematic parameter; low-dimensional parameterization; manipulation task; marker trajectory reconstruction error; optimization technique; pronation-supination joint angles; range of motion; subject-specific kinematic model; surface marker measurement; Biomedical measurements; Bones; Computer science; In vitro; In vivo; Iron; Joints; Kinematics; Read only memory; Robots; Surface reconstruction; Thumb; Axes of rotation; axes of rotation; optimization; subject-specific joint models; thumb mobility; Algorithms; Biomechanics; Carpometacarpal Joints; Computer Simulation; Finger Joint; Humans; Models, Anatomic; Models, Biological; Rotation; Thumb;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2008.919854
  • Filename
    4463655