• DocumentCode
    1091206
  • Title

    Errors Associated With Light-Pipe Radiation Thermometer Temperature Measurements

  • Author

    Yan Qu ; Puttitwong, E. ; Howell, J.R. ; Ezekoye, O.A.

  • Author_Institution
    Adv. Micro Devices Inc., Austin, TX
  • Volume
    20
  • Issue
    1
  • fYear
    2007
  • Firstpage
    26
  • Lastpage
    38
  • Abstract
    Accurate measurement of surface temperature distribution is of concern in the semiconductor industries, particularly in rapid thermal processing. The International Technology Roadmap for Semiconductors 2004 has established requirements of uncertainties of plusmn1.5 degC at a temperature of 1000 degC, with temperature calibration traceable to ITS-90 (International Temperature Scale-1990). Light-pipe radiation thermometers (LPRTs) are becoming increasingly important as an industrial tool for temperature measurement, especially in the semiconductor industry. However, achieving improved accuracy will be difficult without fully understanding several issues associated with LPRTs. In this paper, the "drawdown effect," the "shadow effect," and the "environmental effect" are investigated. The drawdown effect is caused by the physical mass of the light-pipe probe acting as a radiation heat sink for the measured object. The shadow effect is caused by distortion of the wafer radiosity distribution due to the presence of the light-pipe probe. The environmental effect is caused by nonspecular reflection due to surface imperfection or impurity of the light-pipe material. Monte Carlo simulation was conducted to better understand the underlying physics, and the simulation results are compared to the experiment results. The latter two effects were found to be very important in the present study
  • Keywords
    Monte Carlo methods; calibration; measurement uncertainty; rapid thermal processing; temperature distribution; temperature measurement; thermometers; 1000 C; ITS-90; Monte Carlo simulation; errors; light-pipe radiation thermometer; measurement uncertainties; nonspecular reflection; radiation heat sink; rapid thermal processing; semiconductor industries; shadow effect; surface imperfection; surface impurity; surface temperature distribution; temperature calibration; temperature measurement; wafer radiosity distribution; Calibration; Distortion measurement; Electronics industry; Heat sinks; Optical reflection; Particle measurements; Probes; Rapid thermal processing; Temperature distribution; Temperature measurement; Error; light-pipe; radiation thermometer; temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Semiconductor Manufacturing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0894-6507
  • Type

    jour

  • DOI
    10.1109/TSM.2007.890772
  • Filename