    The commenters maintain that the above-titled paper (ibid., vol.39, p.159-64, 1992) contains a flawed derivation of the heart surface source model for the anisotropic case, and that the argument that there will be a particular discontinuity in the body surface electrocardiographic waveform is based on a questionable picture of the time course of the area of breakthrough. The author responds that there is a flow in the commenters´ argument that is one of the consequences of his work, and he elaborates on the matter.<>
  • Keywords
    bioelectric potentials; electrocardiography; physiological models; anisotropic case; body surface electrical potentials; breakthrough area time course; heart surface source model; imaging parameters; oblique dipole layer cardiac generator; Anisotropic magnetoresistance; Biomedical engineering; Biomedical imaging; Conductors; Equations; Heart; Muscles; Predictive models; Surface waves; Action Potentials; Computer Simulation; Electrocardiography; Heart; Humans;