    A Wireless IC for Wide-Range Neurochemical Monitoring Using Amperometry and Fast-Scan Cyclic Voltammetry

  • Author

    Roham, M. ; Daberkow, D.P. ; Ramsson, E.S. ; Covey, D.P. ; Pakdeeronachit, S. ; Garris, P.A. ; Mohseni, P.

  • Author_Institution
    Case Western Reserve Univ., Cleveland
  • Volume
    2
  • Issue
    1
  • fYear
    2008
  • fDate
    3/1/2008 12:00:00 AM
  • Firstpage
    3
  • Lastpage
    9
  • Abstract
    An integrated circuit for real-time wireless monitoring of neurochemical activity in the nervous system is described. The chip is capable of conducting measurements in both fast-scan cyclic voltammetry (FSCV) and amperometry modes for a wide input current range. The chip architecture employs a second-order DeltaSigma modulator (DeltaSigmaM) and a frequency-shift-keyed transmitter operating near 433 MHz. It is fabricated using the AMI 0.5-mum double-poly triple-metal n-well CMOS process, and requires only one off-chip component for operation. A measured current resolution of 12 pA at a sampling rate of 100 Hz and 132 pA at a sampling rate of 10 kHz is achieved in amperometry and 300-V/s FSCV modes, respectively, for any input current in the range of plusmn430 nA. The modulator core and the transmitter draw 22 and 400 muA from a 2.6-V power supply, respectively. The chip has been externally interfaced with a carbon-fiber microelectrode implanted acutely in the caudate-putamen of an anesthetized rat, and, for the first time, extracellular levels of dopamine elicited by electrical stimulation of the medial forebrain bundle have been successfully recorded wirelessly using 300-V/s FSCV.
  • Keywords
    CMOS integrated circuits; amperometric sensors; biochemistry; bioelectric potentials; biomedical electrodes; brain; cellular biophysics; microelectrodes; neurophysiology; voltammetry (chemical analysis); wireless sensor networks; amperometry; anesthetized rat; carbon-fiber microelectrode; current 12 pA; current 132 pA; current resolution; double-poly triple-metal n-well CMOS process; electrical stimulation; extracellular dopamine levels; fast-scan cyclic voltammetry; frequency 10 kHz; frequency 100 Hz; frequency-shift-keyed transmitter; medial forebrain bundle; modulator core; nervous system; neurochemical activity monitoring; second-order delta-sigma modulator; voltage 2.6 V; wireless integrated circuit; Current measurement; Delta modulation; Integrated circuit measurements; Monitoring; Nervous system; Power capacitors; Real time systems; Sampling methods; Semiconductor device measurement; Transmitters; Amperometry; delta–sigma modulator; fast-scan cyclic voltammetry (FSCV); neurochemical monitoring; wireless integrated circuit;
  • fLanguage
    English
  • Journal_Title
    Biomedical Circuits and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1932-4545
  • Type

    jour

  • DOI
    10.1109/TBCAS.2008.918282
  • Filename
    4469299