• DocumentCode
    1096090
  • Title

    Elliptical-Tukey Chirp Signal for High-Resolution, Air-Coupled Ultrasonic Imaging

  • Author

    Pallav, Prakash ; Gan, Tat Hean ; Hutchins, David A.

  • Author_Institution
    Warwick Univ., Coventry
  • Volume
    54
  • Issue
    8
  • fYear
    2007
  • fDate
    8/1/2007 12:00:00 AM
  • Firstpage
    1530
  • Lastpage
    1540
  • Abstract
    A new signal processing method, which uses a modified chirp signal for air-coupled ultrasonic imaging, is described. A combination of the elliptical and Tukey window functions has been shown to give a better performance than the Hanning windowing used in most pulse- compression algorithms for air-coupled applications. The elliptical-Tukey chirp signal provides an improvement in both the resolution of images and signal-to-noise ratios. In addition, this type of signal also reduces the level of signal voltages required to drive the source transducer while maintaining the performance of the system. This approach, thus, may have wide interest in all forms of wide bandwidth ultrasonic imaging.
  • Keywords
    acoustic signal processing; chirp modulation; image resolution; ultrasonic imaging; air-coupled applications; elliptical-Tukey chirp signal; image resolution; pulse compression; signal-to-noise ratios; ultrasonic imaging; window functions; Chirp; Compression algorithms; Image resolution; Pulse compression methods; Signal processing; Signal processing algorithms; Signal resolution; Signal to noise ratio; Ultrasonic imaging; Voltage;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2007.423
  • Filename
    4291502