DocumentCode :
1098790
Title :
Total Dose and Dose Rate Response of an AD590 Temperature Transducer
Author :
Pease, Ronald L. ; Dunham, Gary W. ; Seiler, John E. ; Platteter, Dale G. ; McClure, Steven S.
Author_Institution :
RLP Res., Los Lunas
Volume :
54
Issue :
4
fYear :
2007
Firstpage :
1049
Lastpage :
1054
Abstract :
The total dose response of the Analog Devices AD590 is presented for a variety of irradiation test conditions. The parts packaged in flat-packs show very large enhanced low dose rate sensitive (ELDRS) response for unbiased irradiation, starting at about 20 krad, whereas parts packaged in TO-52 cans are not ELDRS. The reason for this package sensitivity appears to be a result of hydrogen trapped in the cavity of the flat-pack package. The responses at 10 mrad/s and 3 mrad/s are essentially the same, indicating that the low dose rate enhancement factor has leveled off below 10 mrad/s. Elevated temperature irradiation at 100degC and 5 rad/s does not simulate the low dose rate response.
Keywords :
dosimetry; transducers; Analog Devices AD590 temperature transducer; dose rate enhancement factor; dose rate response; package sensitivity; temperature 100 C; total dose response; Circuits; Cranes; Current density; Hydrogen; Packaging; Resistors; Temperature sensors; Testing; Transducers; Voltage; Dose rate; enhanced low-dose-rate sensitivity; radiation effects; temperature transducer; total ionizing dose;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2007.892262
Filename :
4291775
Link To Document :