    Optimization of Measurement Arrangements for Magnetic Detection Electrical Impedance Tomography

  • Author

    Liling Hao ; Gang Li ; Ling Lin

  • Author_Institution
    Coll. of Precision Instrum. & Opto-Electron. Eng., Tianjin Univ., Tianjin, China
  • Volume
    61
  • Issue
    2
  • fYear
    2014
  • fDate
    Feb. 2014
  • Firstpage
    444
  • Lastpage
    452
  • Abstract
    Magnetic detection electrical impedance tomography (MDEIT) is an imaging modality that aims to compute the cross-sectional distribution of the conductivity inside a volume. The current is injected into the volume by the surface electrodes and the resulting magnetic fields surrounding the object are detected by coils. The image resolution and contrast in MDEIT image reconstruction are affected by the parameters such as the numbers and locations of electrodes and measurements, and the finite-element mesh resolution. This paper addresses the numerical experiment applied to the singular value analysis (SVA) of the sensitivity matrix in the presence of noisy measurements, subsequently suggesting the optimal electrode and detector configurations for the whole imaging object region. For the region of interest (RoI), the combined SVA and redundancy reduction is used to obtain the optimum measurement arrangement. Finally, the optimum design is confirmed by examining the image reconstructions of the simulated data acquired with different measurement arrangements. The results indicate that properly increasing the number of current injections and the number of measurement circles, and locating preferentially the electrodes and detectors on the region nearest to the RoI produce more useful singular values and better reconstructed images. These results provide guidelines for the design of the MDEIT experimental system.
  • Keywords
    biomedical electrodes; data acquisition; electric impedance imaging; electric impedance measurement; image reconstruction; image resolution; medical image processing; singular value decomposition; MDEIT image reconstruction; RoI; SVA; finite-element mesh resolution; image resolution; magnetic detection electrical impedance tomography; magnetic fields; measurement arrangements; noisy measurements; numerical analysis; redundancy reduction; region-of-interest; simulated data acquisition; singular value analysis; surface electrodes; whole imaging object region; Conductivity; Current measurement; Density measurement; Electrodes; Image reconstruction; Magnetic flux density; Noise level; Magnetic detection electrical impedance tomography (MDEIT); optimum measurement arrangement; redundancy reduction; region of interest (RoI); singular value analysis (SVA);
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2013.2280632
  • Filename
    6588930