DocumentCode :
1099910
Title :
Notes on the Synchronous Commutator
Author :
Whitehead, J.B. ; Isshiki, T.
Author_Institution :
Professor of Electrical Engineering, Johns Hopkins University
Issue :
1
fYear :
1920
Firstpage :
407
Lastpage :
441
Abstract :
In the use of the synchronous commutator in series connection as a suppressor, serious errors may arise due to relatively small amounts of capacity in the commutator and galvanometer circuits. The magnitude of these errors is studied for a number of different connections, and methods for eliminating them are pointed out. A number of wave forms are given, indicating the nature of the errors. Used as a shunt suppressor the commutator is far more reliable and this method of connection is always to be preferred. An appendix gives a theoretical analysis of two cases investigated and shows a close agreement with the experimental observations.
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1920.4764968
Filename :
4764968
Link To Document :
بازگشت