DocumentCode
1100265
Title
The Operating Frequency of Regenerative Oscillatory Systems
Author
Benioff, Hugo
Author_Institution
Carnegie Institution of Washington, Seismological Research, Seismological Laboratory, Pasadena, California
Volume
19
Issue
7
fYear
1931
fDate
7/1/1931 12:00:00 AM
Firstpage
1274
Lastpage
1277
Abstract
The operating frequency of regenerative oscillatory systems is quantitatively derived in terms of the natural frequency, the damping constant, and the phase of the driving force. As an example the results are used to calculate the change in rate of a pendulum clock due to a given variation in the phase of the driving impulses. Applications to other types of systems are briefly indicated.
Keywords
Clocks; Damping; Equations; Frequency; Laboratories; Oscillators; Power amplifiers; Seismology; Steady-state; Vibrations;
fLanguage
English
Journal_Title
Radio Engineers, Proceedings of the Institute of
Publisher
ieee
ISSN
0731-5996
Type
jour
DOI
10.1109/JRPROC.1931.222450