DocumentCode :
1100579
Title :
Comparison of the nature of torque production in reluctance and induction motors
Author :
Hsu, John S. ; Liou, Shy-Shenq P. ; Woodson, Herbert H.
Author_Institution :
Center for Electromech., Texas Univ., Austin, TX, USA
Volume :
5
Issue :
2
fYear :
1990
fDate :
6/1/1990 12:00:00 AM
Firstpage :
304
Lastpage :
309
Abstract :
The nature of torque production is different in reluctance and inductance motors. One significant difference occurs in a reluctance motor that has nonsalient stator punching and a salient motor. When the flux per pole is small in such a motor, the torque can still be high, as long as the rate of energy change with respect to the rotor angular displacement at the rotor pole fronts and pole ends is high. A theoretical foundation to improve the torque capability of reluctance motors is provided. Effects of saturation and stray-load loss are also studied. Experimental results show agreement with theoretical conclusions
Keywords :
induction motors; reluctance motors; torque; energy change; flux per pole; induction motors; nonsalient stator punching; reluctance motor; rotor angular displacement; salient motor; saturation; stray-load loss; torque production; Air gaps; Copper; Induction motors; Production; Punching; Reluctance motors; Rotors; Stators; Student members; Torque;